Palo Alto Networks Systems Engineer Professional - Software Firewall Sample Questions:
1. A prospective customer wants to deploy VM-Series firewalls in their on-premises data center, CN-Series firewalls in Azure, and Cloud NGFWs in Amazon Web Services (AWS). They also require centralized management.
Which solution meets the requirements?
A) NGFW Software credits, Cloud NGFW, and Strata Cloud Manager (SCM)
B) Fixed VM-Series firewalls, Cloud NGFW credits, and Panorama
C) NGFW Software credits and Panorama
D) NGFW Software credits and Strata Cloud Manager (SCM)
2. Which two software firewall types can protect egress traffic from workloads attached to an Azure vWAN hub? (Choose two.)
A) VM-Series
B) CN-Series
C) Cloud NGFW
D) PA-Series
3. Which capability, as described in the Securing Applications series of design guides for VM-Series firewalls, is common across Azure, GCP, and AWS?
A) BGP dynamic routing to peer with cloud and on-premises routers
B) Horizontal scalability through cloud-native load balancers
C) Site-to-site VPN
D) GlobalProtect portal and gateway services
4. What are two benefits of using Palo Alto Networks NGFWs in a public cloud service provider (CSP) environment? (Choose two.)
A) Deployable in any CSP environment
B) Automated scaling
C) Consistent Security policies throughout the multi-cloud environment
D) Management of all network traffic in every CSP environment
5. A company wants to make its flexible-license VM-Series firewall, which runs on ESXi, process higher throughput.
Which order of steps should be followed to minimize downtime?
A) 1. Power-off the VM and increase the vCPUs within the hypervisor.
2. Power-on the VM-Series NGFW.
3. Retrieve or fetch license keys on the VM-Series NGFW.
4. Increase the vCPU within the deployment profile.
5. Confirm the correct tier level and vCPU appear on the NGFW dashboard.
B) 1. Power-off the VM and increase the vCPUs within the hypervisor.
2. Increase the vCPU within the deployment profile.
3. Retrieve or fetch license keys on the VM-Series NGFW.
4. Confirm the correct tier level and vCPU appear on the NGFW dashboard.
5. Power-on the VM-Series NGFW.
C) 1. Increase the vCPU within the deployment profile.
2. Retrieve or fetch license keys on the VM-Series NGFW.
3. Confirm the correct tier level and vCPU appear on the NGFW dashboard.
4. Power-off the VM and increase the vCPUs within the hypervisor.
5. Power-on the VM-Series NGFW.
D) 1. Increase the vCPU within the deployment profile.
2. Retrieve or fetch license keys on the VM-Series NGFW.
3. Power-off the VM and increase the vCPUs within the hypervisor.
4. Power-on the VM-Series NGFW.
5. Confirm the correct tier level and vCPU appear on the NGFW dashboard.
Solutions:
| Question # 1 Answer: C | Question # 2 Answer: A,C | Question # 3 Answer: B | Question # 4 Answer: B,C | Question # 5 Answer: B |
We're so confident of our products that we provide no hassle product exchange.


By Harold

