NETA NETA_2 Exam Overview:
| Certification Vendor: | InterNational Electrical Testing Association (NETA) |
| Exam Name: | NETA Level 2 Certified Assistant Electrical Testing Specialist (Certified Assistant Technician) |
| Exam Number: | NETA_2 |
| Real Exam Qty: | 100 multiple-choice questions |
| Available Languages: | English |
| Exam Format: | Closed-book, Proctored onsite exam, Multiple-choice |
| Passing Score: | Scaled score 410 (200–500 scale) |
| Related Certifications: | NETA Level 1 Trainee Technician NETA Level 3 Certified Technician NETA Level 4 Certified Senior Technician |
| Exam Duration: | 120 minutes |
| Recommended Training: | NETA Certification Exam Preparation Resources |
| Exam Registration: | NETA Official Website |
| Sample Questions: | NETA NETA_2 Sample Questions |
| Exam Way: | Onsite proctored examination (closed-book) |
| Pre Condition: | Must meet Level 1 requirements; typically 2 years of related experience plus 40 hours safety training and 160 hours electrical training (or equivalent technical education). Must be employed by or affiliated with a NETA Accredited Company. |
| Official Syllabus URL: | https://www.netaworld.org |
NETA NETA_2 Exam Syllabus Topics:
| Section | Weight | Objectives |
|---|---|---|
| Topic 1: Systems and Commissioning | 5% | - System-Level Testing
|
| Topic 2: Component Testing | 55% | - Electrical Equipment Testing
|
| Topic 3: Electrical Testing Fundamentals and Theory | 25% | - Measurement Principles
|
| Topic 4: Safety | 15% | - Electrical Safety Fundamentals
|
NETA Level 2 Certified Assistant Electrical Testing Specialist Sample Questions:
1. Cells are connected inparallelin order to increase:
A) Voltage rating
B) Internal resistance
C) Power factor
D) Current capacity
2. When making a resistance measurement, which ohmmeter range should be selectedinitially?
A) Auto-range only
B) Lowest resistance range
C) Highest resistance range
D) Mid-scale range
3. Determine theRMS voltageof a sinusoidal waveform displayed on an oscilloscope showing 0.45 V peak with a vertical sensitivity of 0.2 V/division.
A) 0.45 V
B) 0.64 V
C) 0.32 V
D) 0.20 V
4. In azone-interlocked low-voltage circuit breakerscheme, if the breaker responsible for clearing a fault fails to operate, which statement is correct?
A) All breakers will trip simultaneously
B) The upstream breaker will trip immediately
C) The downstream breaker will trip
D) The fault will remain uncleared
5. You arrive to perform acceptance testing on a newly installed indoor 15 kV switchgear lineup. Covers are removed and conductors are exposed with taped ends. What is thecorrect initial action?
A) Verify the source is de-energized and apply lockout
B) Assume the equipment is safe since it is new
C) Proceed with visual inspection only
D) Begin insulation resistance testing
Solutions:
| Question # 1 Answer: D | Question # 2 Answer: B | Question # 3 Answer: C | Question # 4 Answer: C | Question # 5 Answer: A |