[2021] Use Valid Exam NS0-516 by SurePassExams Books For Free Website
Free NCIE SAN E-Series NS0-516 Official Cert Guide PDF Download
NetApp NS0-516 Exam Certification Details:
| Exam Price | $150 USD |
| Recommended Training | E-Series Fundamentals (WBT) Configuring and Monitoring NetApp E-Series and EF-Series Storage Systems (ILT) |
| Duration | 90 minutes |
| Number of Questions | 60 |
| Exam Name | Implementation Engineer SAN Specialist E-Series |
| Exam Code | NS0-516 NCIE SAN Specialist E-Series |
| Sample Questions | NetApp NS0-516 Sample Questions |
| Exam Registration | PEARSON VUE |
NetApp NS0-516 Exam Topics:
| Section | Objectives |
|---|---|
| Management | -Describe the administrative tasks for managing E-Series systems with SANtricity System Manager. -Describe the management security features in SANtricity System Manager and SANtricity Unified Manager. -Describe when and how to configure and use SANtricity Unified Manager. |
| Host Side | -Describe the different host connection options for E-Series systems. -Describe how to configure hosts for multipathing. |
| SAN | -Describe the end-to-end network configuration for Fibre Channel and Ethernet. |
| Troubleshooting | -Demonstrate the steps for troubleshooting an E-Series system. -Demonstrate how to analyze multipathing issues between a host and an E-Series system. |
| Documentation | -Describe the process of reviewing and preparing a site for implementation of E-Series. -Describe the information you give a customer after deploying a solution. |
| Storage Configuration | -Describe how to setup alerting and notification for the E-Series system. -Describe how to create and administer Volume Groups or DDP and associated volumes. -Describe physical and logical storage requirements. -Describe the setup of CHAP for an iSCSI environment. -Describe when to use DDP or Volume Groups. |
| Toolbox | -Describe the tools required to design and implement an E-Series solution. |
NEW QUESTION 38
What is the 'base' host connectivity provided by the E5500 Controller? (Choose the best answer.)
- A. SAS
- B. FC
- C. iSCSI
- D. iSCSI
- E. IB
Answer: B
NEW QUESTION 39
Which file contains the configuration for a multipath driver for FC on Linux systems?
- A. /etc/multipath.conf
- B. /etc/kernel/mp.conf
- C. /etc/dm-multipath.conf
- D. /opt/multipath/multipath.cnf
Answer: A
NEW QUESTION 40
In-band communication occurs between which entities?
- A. One of the data I/O hosts and the controllers
- B. The management host and the Ethernet management ports
- C. The ESM and the I/O host
- D. One of the data I/O host's Ethernet port 1 and the expansion shelves
Answer: A
NEW QUESTION 41
The ability of many E-Series controllers to hold an additional firmware image in reserve _________. (Choose the best answer.)
- A. allows controller firmware to be downloaded immediately and activated at a later time
- B. is used for Support use only
- C. is used to store a backup boot image
- D. allows two firmware images to be used at the same time
Answer: D
NEW QUESTION 42
What should you do to confirm a component failure prior to replacing hardware? (Choose the best answer.)
- A. Run chkdsk on the client
- B. Run the Recovery Guru
- C. Power cycle the storage array
- D. Check the Major Events Log
Answer: B
NEW QUESTION 43
Which three methods can be used to increase the space available to clients? (Choose three.)
- A. Replace some HDD with SSD
- B. Fill empty drive slots in the array
- C. Create new volume groups from unconfigured capacity
- D. Increase volume segment size
- E. Convert RAID-6 volume group to RAID-5
Answer: B,C,D
NEW QUESTION 44
The out-of-band connection is an Ethernet connection from the storage manager host to the LAN, and from the LAN to which location?
- A. port 1 of the I/O host
- B. port 2 of the ESM
- C. port E of the controller
- D. port 1 of the controller
Answer: D
NEW QUESTION 45
Exhibit:
An administrator is asked to create a 5532 GiB volume from the volume group.
Referring to the exhibit how would the administrator complete this request?
- A. Create the volume after consolidating the capacity
- B. Create the volume after performing space reclamation
- C. Create the volume after adjusting the preservation capacity
- D. Create the volume from the available capacity
Answer: D
NEW QUESTION 46
How many paths provide optimal redundancy from a host through a switched topology to a storage system?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: B
NEW QUESTION 47
A customer is configuring an EF570 system on an internal network. Due to security concerns, the network does not have Internet access. The customer wants to regularly send standard support data to NetApp.
In this scenario, what should the customer do to accomplish this task?
- A. Open a support ticket with NetApp to enable AutoSupport local functionality, manually move the data to a server with Internet access, and then send the data to NetApp.
- B. Enable AutoSupport with a set interval and with the store locally option selected, manually move the data to a server with Internet access, and then send the data to NetApp.
- C. Set up a script to initiate Collect Support Data on a set interval, manually move the data to a server with Internet access, and then send the data to NetApp.
- D. Set up a script to initiate Collect Support Data, remove the extra log files, manually move the data to a server with Internet access, and then send the data to NetApp.
Answer: B
NEW QUESTION 48
What is SMutil? (Choose the best answer.)
- A. a GUI or CLI run on a host server used for storage system management
- B. a host server process that enables storage system management with the storage data path
- C. an OS-dependent collection of utilities for servers attached to SANtricity-managed storage systems
- D. inter-process communication that supports computer program subroutines
- E. a host I/O performance modeling interface
Answer: C
NEW QUESTION 49
Which item can be downloaded concurrently with controller firmware? (Choose the best answer.)
- A. Drive firmware
- B. ESM firmware
- C. NVSRAM
- D. SANtricity software
Answer: C
NEW QUESTION 50
Your company has deployed an E2824 and has decided to change the host protocol from iSCSI to FC You use the storage array profile to review the installed SFPs.
In this scenario, which set of supported data rates indicates that you are using dual-purpose SFPs?
- A. 25 Gbps, 10 Gbps
- B. 16 Gbps, 8 Gbps, 4 Gbps
- C. 16 Gbps, 10 Gbps, 8 Gbps, 4 Gbps
- D. 32 Gbps, 16 Gbps, 8 Gbps, 4 Gbps
Answer: C
NEW QUESTION 51
What would be the minimum configuration required to support a drawer-protected 20-drive DDP? (Choose the best answer.)
- A. An E2712 with one DE6600 Expansion Chassis, containing a total of 72, 3TB NL-SAS drives.
- B. An E5460 with one DE6600 Expansion Chassis, containing a total of 120, 3TB NL-SAS drives.
- C. An E2624 with four DE5600 Expansion Chassis, containing a total of 6, 1.6TB SSD and 96, 3T NL-SAS drives.
- D. An E5424 with one DE5600 Expansion Chassis, containing a total of 48, 900GB SAS drives.
Answer: B
NEW QUESTION 52
To discover events that need to be reported to the storage administrator, which log does the Event Monitor poll?
- A. Major Event Log
- B. Recovery Guru log
- C. ASUP log
- D. Array Profile
Answer: A
NEW QUESTION 53
What is the first step when replacing a FRU component on a running storage system? (Choose the best answer.)
- A. Power down the array before changing the part.
- B. Disconnect the cables from the management ports.
- C. Use SANtricity to view the target component and place the component off-line or in service mode before removing the part.
- D. Remove the part and check SANtricity for continuing errors.
Answer: C
NEW QUESTION 54
You are helping a customer diagnose a performance issue on an E-Series storage system. You decide to measure the amount of data that is being handled over the span of an hour.
In this scenario, what are you measuring?
- A. IOPS
- B. I/O alignment
- C. parity
- D. throughput
Answer: D
NEW QUESTION 55
With a system cache block size of 32K, how much cache space per I/O is "lost" if incoming I/Os are all 48K writes? (Choose the best answer.)
- A. 24K
- B. 0 - no space is lost
- C. 16K
- D. 4K
- E. 8K
Answer: C
NEW QUESTION 56
A company wants the most scalable host-side connection topology for E-Series systems. In this scenario, which FC topology would satisfy the requirement?
- A. fabric attach
- B. private loop
- C. arbitrated loop
- D. direct connect
Answer: A
NEW QUESTION 57
Which three documents should be provided to the customer after the e-Series installation is complete?
(choose three.)
- A. a document showing available power on the UPS with no equipment connected
- B. a b a document with IMT pages that show the supported host configuration and fabric switches in the solution
- C. a document showing user IDs and passwords for all deployed devices
- D. a document showing the cabinet layout with cabling information and IP addresses being used
- E. a document showing how much space is available for system expansion
Answer: B,C,D
NEW QUESTION 58
Identify this image.
- A. E5600 controller
- B. E2700 controller
- C. DE5612 ESM
- D. DE6600 ESM
Answer: A
NEW QUESTION 59
What would an E-Series system customer use to determine when a specific volume was deleted?
- A. Storage Array Profile
- B. Online Help
- C. Recovery Guru
- D. Event Log
Answer: D
NEW QUESTION 60
......
Network Appliance NS0-516 Official Cert Guide PDF: https://www.surepassexams.com/NS0-516-exam-bootcamp.html
Exam NS0-516: NetApp Implementation Engineer SAN Specialist E-Series (NCIE) - SurePassExams: https://drive.google.com/open?id=1BTHoaNR7TapFlpldtv6tiorkUfJZ-3wW